(ii) the testing is performed in accordance with §117.335 of this title after March 31, 2005, and prior to September 30, 2005, while operating at maximum rated capacity, or as near thereto as practicable. For the time period from March 31, 2005, to September 30, 2005, the results of this testing must be used for demonstrating compliance with the emission specifications in §117.310(a) of this title or to quantify the emissions for units subject to the mass emissions cap and trade program of Chapter 101, Subchapter H, Division 3 of this title; (iii) for units that a totalizing fuel flow meter has not been installed as required in §117.340(a) of this title, the maximum rated capacity of the unit must be used to quantify the emissions for units subject to the mass emissions cap and trade program of Chapter 101, Subchapter H, Division 3 of this title; and (iv) if the unit is not shut down by September 30, 2005, the owner or operator will be considered in violation of this section as of March 31, 2005, and extensions beyond September 30, 2005, will not be granted. |