TITLE 30ENVIRONMENTAL QUALITY
PART 1TEXAS COMMISSION ON ENVIRONMENTAL QUALITY
CHAPTER 115CONTROL OF AIR POLLUTION FROM VOLATILE ORGANIC COMPOUNDS
SUBCHAPTER CVOLATILE ORGANIC COMPOUND TRANSFER OPERATIONS
DIVISION 4CONTROL OF VEHICLE REFUELING EMISSIONS (STAGE II) AT MOTOR VEHICLE FUEL DISPENSING FACILITIES
RULE §115.244Inspection Requirements

The owner or operator of any gasoline dispensing facility subject to the control requirements of this division shall conduct daily inspections of the Stage II vapor recovery system for the defects specified in §115.242(d)(3) and (4) of this title (relating to Control Requirements) as follows.

  (1) For all systems, the daily inspections must include the applicable portions of §115.242(d)(3)(A) - (F), (H), and (K), and (4) of this title.

  (2) For assist systems that use a processor, indicating mechanisms designed by the Stage II vapor recovery equipment manufacturer to verify proper operation must be inspected daily. Examples of these indicating mechanisms include flame detection sensors, remote (from the processor) visual or audible displays indicating system operation, or other means as described in the applicable Executive Order for the system.

  (3) For all systems, the components listed in §115.242(d)(3)(J) of this title must be inspected at least monthly.

  (4) For all systems, the components listed in §115.242(d)(3)(G) of this title must be inspected at least annually.


Source Note: The provisions of this §115.244 adopted to be effective November 16, 1992, 17 TexReg 7782; amended to be effective December 3, 1993, 18 TexReg 8538; amended to be effective November 27, 2002, 27 TexReg 10935; amended to be effective October 31, 2013, 38 TexReg 7453