Figure: 30 TAC §117.320(c)(3)

The equation for calculating the daily cap measured in pounds per day for all electric generating facilities included in the system cap.

Where:

     Capdaily = the NOX maximum daily cap in pounds per day;

     i = as defined in paragraph (1) of this subsection;

     N = as defined in paragraph (1) of this subsection;

     Hmi = the maximum heat input, as certified to the executive director, allowed or possible
               (whichever is lower) in a day; and

     Ri = as defined in paragraph (1) of this subsection.