Figure: 30 TAC §113.2174(h)

Table 8. Requirements for Stack Tests

Pollutant Method in 40 CFR Part
60, Appendix A to
Determine Sampling
Location
Method in 40 CFR
Part 60, Appendix
A to Measure
Pollutant
Concentration
Also Note the Following Information
1. Organics:
      Dioxins/Furans
Method 1 Method 23a The minimum sampling time must be 4 hours per test
run while the municipal waste combustion unit is
operating at full load
2. Metals:
      Cadmium
Method 1 Method 29a Compliance testing must be performed while the
municipal waste combustion unit is operating at full
load
      Lead Method 1 Method 29a Compliance testing must be performed while the
municipal waste combustion unit is operating at full
load
      Mercury Method 1 Method 29a Compliance testing must be performed while the
municipal waste combustion unit is operating at full
load
      Opacity Method 9 Method 9 Use Method 9 to determine compliance with opacity
limits.  3-hour observation period (thirty 6-minute
averages)
      Particulate Matter Method 1 Method 5 or 29 The minimum sample volume must be 1.0 cubic meters.
The probe and filter holder heating systems in the
sample train must be set to provide a gas temperature no
greater than 
160  ±14°C.  The minimum sampling time is 1 hour
3. Acid Gasesb
      Hydrogen Chloride
Method 1 Method 26 or 26Aa Test runs must be at least 1 hour long while the
municipal waste combustion unit is operating at full
load
4. Otherb
      Fugitive Ash
Not applicable Method 22
(visible emissions)
The three 1-hour observation period must include
periods when the facility transfers fugitive ash from the
municipal waste combustion unit to the area where the
fugitive ash is stored or loaded into containers or trucks

aMust simultaneously measure oxygen (or carbon dioxide) using Method 3A or 3B in 40 CFR Part 60, Appendix A.

bUse CEMS to test sulfur dioxide, nitrogen oxide, and carbon monoxide.  Stack tests are not required except for quality assurance requirements in 40 CFR Part 60, Appendix F.