Figure: 30 TAC §335.590(24)(F)(vi)
"I (Texas Licensed Professional Engineer) , Texas P.E. Registration Number , certify
under penalty of law that I have personally examined and am familiar with the design and
construction of the dikes that are a portion of (unit name) .
I further certify that I have evaluated the dike design and materials of construction using accepted
engineering procedures, and have determined that the dike has structural integrity, and:
(I) Will withstand the stress of the pressure exerted by the types and amounts of wastes to
be placed in the unit; and
(II) Will not fail due to scouring or piping, without dependence on any liner system
included in the unit construction.
(Signature) Date: ______________
(SEAL)"