Figure: 30 TAC §113.2075(a)(3)(B)
Table 7. Emission Violation Triggers.
CONTROL METHOD | OPERATING PARAMETER (3-hour rolling averages) |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
Dry Scrubber followed by a Fabric Filter | > Max. Charge Rate and <Min. Secondary Chamber Temp. |
![]() |
||||||||
>Max. Charge Rate and > Max. Fabric Filter Inlet Temp. and <Min. Dioxin/furan Sorbent Flow Rate |
![]() |
|||||||||
> Max. Charge Rate and <Min. HCl Sorbent Flow Rate |
![]() |
|||||||||
>Max. Charge Rate and <Min. Hg Sorbent Flow Rate |
![]() |
|||||||||
Use of Bypass Stack (except during startup, shutdown, or malfunction) |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
||||
Wet Scrubber | >Max. Charge Rate and <Min. Pressure Drop Across Wet Scrubber or <Min. Horsepower to Wet Scrubber or <Min. Amperage to Wet Scrubber |
![]() |
||||||||
> Max. Charge Rate and <Min. Secondary Chamber Temp. |
![]() |
|||||||||
> Max. Charge Rate and <Min. Secondary Chamber Temp. and <Min. Wet Scrubber Liquor Flow Rate |
![]() |
|||||||||
> Max. Charge Rate and <Min. Wet Scrubber Liquor pH |
![]() |
|||||||||
> Max. Charge Rate and >Max. Flue Gas Temp. |
![]() |
|||||||||
Use of Bypass Stack (except during startup, shutdown, or malfunction) |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
||||
Dry Scrubber followed by a Fabric Filter and a Wet Scrubber | > Max. Charge Rate and <Min. Secondary Chamber Temp. |
![]() |
||||||||
>Max. Charge Rate and > Max. Fabric Filter Inlet Temp. and <Min. Dioxin/furan Sorbent Flow Rate |
![]() |
|||||||||
> Max. Charge Rate and <Min. Wet Scrubber Liquor pH |
![]() |
|||||||||
>Max. Charge Rate and <Min. Hg Sorbent Flow Rate |
![]() |
|||||||||
Use of Bypass Stack (except during startup, shutdown, or malfunction) |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
Footnotes:
1 If a CO CEMS is used, the violation of the CO emissions limit is determined by the CEMS.