Figure: 30 TAC §113.2075(a)(3)(B)

Table 7. Emission Violation Triggers.

CONTROL METHOD OPERATING PARAMETER
(3-hour rolling averages)
30_0113_2075-8.gif (1122 bytes) 30_0113_2075-9.gif (1139 bytes) 30_0113_2075-10.gif (1054 bytes) 30_0113_2075-11.gif (1158 bytes) 30_0113_2075-12.gif (1072 bytes) 30_0113_2075-13.gif (1149 bytes) 30_0113_2075-14.gif (918 bytes) 30_0113_2075-15.gif (990 bytes) 30_0113_2075-16.gif (986 bytes)
Dry Scrubber followed by a Fabric Filter > Max. Charge Rate
and
<Min. Secondary Chamber Temp.
  30_0113_2075-17.gif (58 bytes)1              
>Max. Charge Rate
and
> Max. Fabric Filter Inlet Temp.
and
<Min. Dioxin/furan Sorbent Flow Rate
    30_0113_2075-17.gif (58 bytes)            
> Max. Charge Rate
and
<Min. HCl Sorbent Flow Rate
      30_0113_2075-17.gif (58 bytes)          
>Max. Charge Rate
and
<Min. Hg Sorbent Flow Rate
                30_0113_2075-17.gif (58 bytes)
Use of Bypass Stack
(except during startup, shutdown, or malfunction)
30_0113_2075-17.gif (58 bytes)   30_0113_2075-17.gif (58 bytes) 30_0113_2075-17.gif (58 bytes)     30_0113_2075-17.gif (58 bytes) 30_0113_2075-17.gif (58 bytes) 30_0113_2075-17.gif (58 bytes)
Wet Scrubber >Max. Charge Rate
and
<Min. Pressure Drop Across Wet Scrubber
or
<Min. Horsepower to Wet Scrubber
or
<Min. Amperage to Wet Scrubber
30_0113_2075-17.gif (58 bytes)                
> Max. Charge Rate
and
<Min. Secondary Chamber Temp.
  30_0113_2075-17.gif (58 bytes)1              
> Max. Charge Rate
and
<Min. Secondary Chamber Temp.
and
<Min. Wet Scrubber Liquor Flow Rate
    30_0113_2075-17.gif (58 bytes)            
> Max. Charge Rate
and
<Min. Wet Scrubber Liquor pH
      30_0113_2075-17.gif (58 bytes)          
> Max. Charge Rate
and
>Max. Flue Gas Temp.
                30_0113_2075-17.gif (58 bytes)
Use of Bypass Stack
(except during startup, shutdown, or malfunction)
30_0113_2075-17.gif (58 bytes)   30_0113_2075-17.gif (58 bytes) 30_0113_2075-17.gif (58 bytes)     30_0113_2075-17.gif (58 bytes) 30_0113_2075-17.gif (58 bytes) 30_0113_2075-17.gif (58 bytes)
Dry Scrubber followed by a Fabric Filter and a Wet Scrubber > Max. Charge Rate
and
<Min. Secondary Chamber Temp.
  30_0113_2075-17.gif (58 bytes)1              
>Max. Charge Rate
and
> Max. Fabric Filter Inlet Temp.
and
<Min. Dioxin/furan Sorbent Flow Rate
    30_0113_2075-17.gif (58 bytes)            
> Max. Charge Rate
and
<Min. Wet Scrubber Liquor pH
      30_0113_2075-17.gif (58 bytes)          
>Max. Charge Rate
and
<Min. Hg Sorbent Flow Rate
                30_0113_2075-17.gif (58 bytes)
Use of Bypass Stack
(except during startup, shutdown, or malfunction)
30_0113_2075-17.gif (58 bytes)   30_0113_2075-17.gif (58 bytes) 30_0113_2075-17.gif (58 bytes)     30_0113_2075-17.gif (58 bytes) 30_0113_2075-17.gif (58 bytes) 30_0113_2075-17.gif (58 bytes)

Footnotes:

1 If a CO CEMS is used, the violation of the CO emissions limit is determined by the CEMS.