(a) The initial performance test after installation
of the continuous emissions monitoring system (CEMS) for sulfur dioxide
in exhaust gases and the relative accuracy test audits required by
40 Code of Federal Regulations (CFR) Part 60, Appendix F must be conducted
using United States Environmental Protection Agency (EPA) Test Method
6 or 6C (40 CFR Part 60, Appendix A).
(b) Performance tests and relative accuracy test audits
must be conducted using a method in subsection (a) and EPA Test Method
2 (40 CFR Part 60, Appendix A) for exhaust gas flow and following
the measurement site criteria of EPA Test Method 1, §11.1 (40
CFR Part 60, Appendix A), or EPA Test Method 19 (40 CFR Part 60, Appendix
A) for exhaust gas flow in conjunction with the measurement site criteria
of Performance Specification 2, §8.1.3 (40 CFR Part 60, Appendix
B).
(c) Alternate methods as approved by the executive
director and the EPA may be used.
|