(a) Monitoring requirements. The following monitoring
requirements apply to the owner or operator of a solvent cleaning
operation subject to this division that uses a vapor control system
in accordance with §115.463(b) of this title (relating to Control
Requirements). The owner or operator shall install and maintain monitors
to accurately measure and record operational parameters of all required
control devices, as necessary, to ensure the proper functioning of
those devices in accordance with design specifications, including:
(1) continuous monitoring of the exhaust gas temperature
immediately downstream of direct-flame incinerators or the gas temperature
immediately upstream and downstream of any catalyst bed;
(2) the total amount of volatile organic compounds
(VOC) recovered by carbon adsorption or other solvent recovery systems
during a calendar month;
(3) continuous monitoring of carbon adsorption bed
exhaust; and
(4) appropriate operating parameters for vapor control
systems other than those specified in paragraphs (1) - (3) of this
subsection.
(b) Recordkeeping requirements. The following recordkeeping
requirements apply to the owner or operator of a solvent cleaning
operation subject to this division.
(1) The owner or operator shall maintain records of
the testing data, the material safety data sheet, or documentation
of the standard reference texts used to determine the true vapor pressure
of each VOC component, in accordance with the requirements in §115.465(1)
of this title (relating to Approved Test Methods and Testing Requirements).
The concentration of all VOC used to prepare the cleaning solution
and, if diluted prior to use, the proportions that each of these materials
is used must be recorded. Records must be sufficient to demonstrate
continuous compliance with the VOC limits in §115.463(a) and
(e) of this title.
(2) The owner or operator claiming an exemption in
§115.461 of this title (relating to Exemptions) shall maintain
records sufficient to demonstrate continuous compliance with the applicable
exemption criteria.
(3) The owner or operator claiming exemption from this
division in accordance with §115.461(c) of this title shall maintain
records indicating the applicable division the process or operation
is subject to as specified in §115.461(c)(1) of this title and
the control requirements or emission specifications used to control
the VOC emissions from the solvent cleaning operation as specified
in §115.461(c)(2) of this title. The owner or operator shall
also comply with the applicable recordkeeping requirements from the
division the process or operation is subject to sufficient to demonstrate
that the VOC emissions from the solvent cleaning operation are controlled
in accordance with the control requirements or emission specifications
of that division.
(4) The owner or operator shall maintain records of
any testing conducted in accordance with the provisions specified
in §115.465(2) - (4) of this title.
(5) Records must be maintained a minimum of two years
and be made available upon request to authorized representatives of
the executive director, the United States Environmental Protection
Agency, or any local air pollution agency with jurisdiction.
|