<<Prev Rule | Texas Administrative Code |
Next Rule>> |
TITLE 16 | ECONOMIC REGULATION |
PART 1 | RAILROAD COMMISSION OF TEXAS |
CHAPTER 14 | REGULATIONS FOR LIQUEFIED NATURAL GAS (LNG) |
SUBCHAPTER H | LNG TRANSPORTS |
RULE §14.2722 | Liquid Level Gauging Devices |
Truck and trailer containers shall be equipped with a liquid level gauging device of approved design, such as a fixed tube device. Fixed tube devices shall be arranged so that the maximum liquid level to which the container may be filled is set at the maximum permitted for the container based on an initial liquid temperature not to exceed 40 degrees Fahrenheit. An isolation valve shall be installed between the container and the liquid level gauging device. |
Source Note: The provisions of this §14.2722 adopted to be effective May 26, 2003, 28 TexReg 4100 |