RULE §259.146 | Ceilings |
Ceilings within inmate housing areas shall be constructed of a minimum 4" thick concrete plank reinforced with #4 bars 8" on center each way or a minimum 10 gauge steel plate. Innovative design concepts are encouraged and comparable materials and methods approved by the Commission may be utilized for ceiling construction. |
Source Note: The provisions of this §259.146 adopted to be effective December 12, 1994, 19 TexReg 9376; amended to be effective December 10, 1996, 21 TexReg 11626; amended to be effective September 1, 1998, 23 TexReg 8844. |