    (C) declared pregnant women likely to receive during the entire pregnancy, from sources of radiation external to the body, a deep dose equivalent in excess of 0.1 rem (1 mSv); and

    (D) individuals entering a high or very high radiation area;

  (2) notwithstanding paragraph (1)(C) of this subsection, a licensee is exempt from supplying individual monitoring devices to healthcare personnel who may enter a high radiation area while providing patient care if:

    (A) the personnel are not likely to receive, in one year from sources external to the body, a dose in excess of 10% of the limits in subsection (f)(1) of this section; and

    (B) the licensee complies with the requirements of subsection (e)(2) of this section; and

  (3) each licensee shall monitor, to determine compliance with subsection (i) of this section, the occupational intake of radioactive material by and assess the committed effective dose equivalent to:

    (A) adults likely to receive, in one year, an intake in excess of 10% of the applicable ALI in Columns 1 and 2 of Table I of subsection (ggg)(2) of this section;

    (B) minors likely to receive, in one year, a committed effective dose equivalent in excess of 0.1 rem (1 mSv); and

    (C) declared pregnant women likely to receive, during the entire pregnancy, a committed effective dose equivalent in excess of 0.1 rem (1 mSv).

(r) Location and use of individual monitoring devices.

  (1) Each licensee shall ensure that individuals who are required to monitor occupational doses in accordance with subsection (q)(l) of this section wear and use individual monitoring devices as follows.

    (A) An individual monitoring device used for monitoring the dose to the whole body shall be worn at the unshielded location of the whole body likely to receive the highest exposure. When a protective apron is worn, the location of the individual monitoring device is typically at the neck (collar).

    (B) If an additional individual monitoring device is used for monitoring the dose to an embryo/fetus of a declared pregnant woman, in accordance with subsection (m)(1) of this section, it shall be located at the waist under any protective apron being worn by the woman.

    (C) An individual monitoring device used for monitoring the lens dose equivalent, to demonstrate compliance with subsection (f)(1)(B)(i) of this section, shall be located at the neck (collar) or at a location closer to the eye, outside any protective apron being worn by the monitored individual.

    (D) An individual monitoring device used for monitoring the dose to the skin of the extremities, to demonstrate compliance with subsection (f)(1)(B)(ii) of this section, shall be worn on the skin of the extremity likely to receive the highest exposure. Each individual monitoring device, to the extent practicable, shall be oriented to measure the highest dose to the skin of the extremity being monitored.

    (E) An individual monitoring device shall be assigned to and worn by only one individual.

    (F) An individual monitoring device shall be worn for the period of time authorized by the dosimetry processor's certificate of registration or for no longer than three months, whichever is more restrictive.

  (2) Each licensee shall ensure that individual monitoring devices are returned to the dosimetry processor for proper processing.

  (3) Each licensee shall ensure that adequate precautions are taken to prevent a deceptive exposure of an individual monitoring device.

(s) Control of access to high radiation areas.

  (1) The licensee shall ensure that each entrance or access point to a high radiation area has one or more of the following features:

    (A) a control device that, upon entry into the area, causes the level of radiation to be reduced below that level at which an individual might receive a deep dose equivalent of 0.1 rem (1 mSv) in one hour at 30 centimeters (cm) from the source of radiation from any surface that the radiation penetrates;

    (B) a control device that energizes a conspicuous visible or audible alarm signal so that the individual entering the high radiation area and the supervisor of the activity are made aware of the entry; or

    (C) entryways that are locked, except during periods when access to the areas is required, with positive control over each individual entry.

  (2) In place of the controls required by paragraph (1) of this subsection for a high radiation area, the licensee may substitute continuous direct or electronic surveillance that is capable of preventing unauthorized entry.

  (3) The licensee may apply to the agency for approval of alternative methods for controlling access to high radiation areas.

  (4) The licensee shall establish the controls required by paragraphs (1) and (3) of this subsection in a way that does not prevent individuals from leaving a high radiation area.

  (5) The licensee is not required to control each entrance or access point to a room or other area that is a high radiation area solely because of the presence of radioactive materials prepared for transport and packaged and labeled in accordance with the regulations of the United States Department of Transportation (DOT) provided that:

    (A) the packages do not remain in the area longer than three days; and

    (B) the dose rate at 1 meter (m) from the external surface of any package does not exceed 0.01 rem (0.1 mSv) per hour.

  (6) The licensee is not required to control entrance or access to rooms or other areas in hospitals solely because of the presence of patients containing radioactive material, provided that there are personnel in attendance who are taking the necessary precautions to prevent the exposure of individuals to sources of radiation in excess of the established limits in this section and to operate within the ALARA provisions of the licensee's radiation protection program.

(t) Control of access to very high radiation areas. In addition to the requirements in subsection (s) of this section, the licensee shall institute measures to ensure that an individual is not able to gain unauthorized or inadvertent access to areas in which radiation levels could be encountered at 500 rads (5 grays) or more in one hour at 1 m from a source of radiation or any surface through which the radiation penetrates at this level.

(u) Control of access to very high radiation areas for irradiators.

  (1) This subsection applies to licensees with sources of radiation in non-self-shielded irradiators. This subsection does not apply to sources of radiation that are used in teletherapy, in industrial radiography, or in completely self-shielded irradiators in which the source of radiation is both stored and operated within the same shielding radiation barrier and, in the designed configuration of the irradiator, is always physically inaccessible to any individual and cannot create high levels of radiation in an area that is accessible to any individual.

  (2) Each area in which there may exist radiation levels in excess of 500 rads (5 grays) in one hour at 1 m from a source of radiation that is used to irradiate materials shall meet the following requirements.

    (A) Each entrance or access point shall be equipped with entry control devices that:

      (i) function automatically to prevent any individual from inadvertently entering a very high radiation area;

      (ii) permit deliberate entry into the area only after a control device is actuated that causes the radiation level within the area, from the source of radiation, to be reduced below that at which it would be possible for an individual to receive a deep dose equivalent in excess of 0.1 rem (1 mSv) in one hour; and

      (iii) prevent operation of the source of radiation if it would produce radiation levels in the area that could result in a deep dose equivalent to an individual in excess of 0.1 rem (1 mSv) in one hour.

    (B) Additional control devices shall be provided so that, upon failure of the entry control devices to function as required by subparagraph (A) of this paragraph:

      (i) the radiation level within the area, from the source of radiation, is reduced below that at which it would be possible for an individual to receive a deep dose equivalent in excess of 0.1 rem (1 mSv) in one hour; and

      (ii) conspicuous visible and audible alarm signals are generated to make an individual attempting to enter the area aware of the hazard and at least one other authorized individual, who is physically present, familiar with the activity, and prepared to render or summon assistance, aware of the failure of the entry control devices.

    (C) The licensee shall provide control devices so that, upon failure or removal of physical radiation barriers other than the sealed source's shielded storage container: