RULE §291.133Pharmacies Compounding Sterile Preparations

      (i) If the pharmacy is using a biological safety cabinet (BSC) as its PEC for the preparation of hazardous sterile compounded preparations, the biological safety cabinet shall be a Class II or III vertical flow biological safety cabinet located in an ISO Class 7 area that is physically separated from other preparation areas. The area for preparation of sterile chemotherapeutic preparations shall:

        (I) have not less than 0.01 inches water column negative pressure to the adjacent positive pressure ISO Class 7 or better ante-area; and

        (II) have a pressure indicator that can be readily monitored for correct room pressurization.

      (ii) Pharmacies that prepare a low volume of hazardous drugs, are not required to comply with the provisions of clause (i) of this subparagraph if the pharmacy uses a device that provides two tiers of containment (e.g., closed-system vial transfer device within a BSC).

      (iii) If the pharmacy is using a biological safety cabinet as its PEC for the preparation of non-hazardous sterile compounded preparations, the biological safety cabinet shall:

        (I) be located in the buffer area and placed in the buffer area in a manner as to avoid conditions that could adversely affect its operation such as strong air currents from opened doors, personnel traffic, or air streams from the heating, ventilating and air condition system;

        (II) be certified for operational efficiency using certification procedures, such as those outlined in the Certification Guide for Sterile Compounding Facilities (CAG-003-2006), which shall be performed by a qualified independent individual no less than every six months and whenever the device or room is relocated or altered or major service to the facility is performed;

        (III) have pre-filters inspected periodically and replaced as needed, in accordance with written policies and procedures and the manufacturer's specification, and the inspection and/or replacement date documented; and

        (IV) be located in a buffer area that has a minimum differential positive pressure of 0.02 to 0.05 inches water column.

    (C) Compounding aseptic isolator.

      (i) If the pharmacy is using a compounding aseptic isolator (CAI) as its PEC, the CAI shall provide unidirectional airflow within the main processing and antechambers, and be placed in an ISO Class 7 buffer area unless the isolator meets all of the following conditions:

        (I) The isolator must provide isolation from the room and maintain ISO Class 5 during dynamic operating conditions including transferring ingredients, components, and devices into and out of the isolator and during preparation of compounded sterile preparations;

        (II) Particle counts sampled approximately 6 to 12 inches upstream of the critical exposure site must maintain ISO Class 5 levels during compounding operations;

        (III) The CAI must be certified for operational efficiency using certification procedures, such as those outlined in the Certification Guide for Sterile Compounding Facilities (CAG-003-2006), which shall be performed by a qualified independent individual no less than every six months and whenever the device or room is relocated or altered or major service to the facility is performed; and

        (IV) The pharmacy shall maintain documentation from the manufacturer that the isolator meets this standard when located in worse than ISO Class 7 environments.

      (ii) If the isolator meets the requirements in clause (i) of this subparagraph, the CAI may be placed in a non-ISO classified area of the pharmacy; however, the area shall be segregated from other areas of the pharmacy and shall:

        (I) be clean, well lit, and of sufficient size;

        (II) be used only for the compounding of low- and medium-risk, non-hazardous sterile preparations;

        (III) be located in an area of the pharmacy with non-porous and washable floors or floor covering to enable regular disinfection; and

        (IV) be an area in which the CAI is placed in a manner as to avoid conditions that could adversely affect its operation.

      (iii) In addition to the requirements specified in clauses (i) and (ii) of this subparagraph, if the CAI is used in the compounding of high-risk non-hazardous preparations, the CAI shall be placed in an area or room with at least ISO 8 quality air so that high-risk powders weighed in at least ISO-8 air quality conditions, compounding utensils for measuring and other compounding equipment are not exposed to lesser air quality prior to the completion of compounding and packaging of the high-risk preparation.

    (D) Compounding aseptic containment isolator.

      (i) If the pharmacy is using a compounding aseptic containment isolator (CACI) as its PEC for the preparation of low- and medium-risk hazardous drugs, the CACI shall be located in a separate room away from other areas of the pharmacy and shall:

        (I) provide at least 0.01 inches water column negative pressure compared to the other areas of the pharmacy;

        (II) provide unidirectional airflow within the main processing and antechambers, and be placed in an ISO Class 7 buffer area, unless the CACI meets all of the following conditions;

          (-a-) The isolator must provide isolation from the room and maintain ISO Class 5 during dynamic operating conditions including transferring ingredients, components, and devices into and out of the isolator and during preparation of compounded sterile preparations;

          (-b-) Particle counts sampled approximately 6 to 12 inches upstream of the critical exposure site must maintain ISO Class 5 levels during compounding operations;

          (-c-) The CACI must be certified for operational efficiency using certification procedures, such as those outlined in the Certification Guide for Sterile Compounding Facilities (CAG-003-2006), which shall be performed by a qualified independent individual no less than every six months and whenever the device or room is relocated or altered or major service to the facility is performed; and

          (-d-) The pharmacy shall maintain documentation from the manufacturer that the isolator meets this standard when located in worse than ISO Class 7 environments.

      (ii) If the CACI meets all conditions specified in clause (i) of this subparagraph, the CACI shall not be located in the same room as a CAI, but shall be located in a separate room in the pharmacy, that is not required to maintain ISO classified air. The room in which the CACI is located shall provide a minimum of 0.01 inches water column negative pressure compared with the other areas of the pharmacy and shall meet the following requirements:

        (I) be clean, well lit, and of sufficient size;

        (II) be maintained at a temperature of 20 degrees Celsius or cooler and a humidity below 60%;

        (III) be used only for the compounding of hazardous sterile preparations;

        (IV) be located in an area of the pharmacy with walls, ceilings, floors, fixtures, shelving, counters, and cabinets that are smooth, impervious, free from cracks and crevices, non-shedding and resistant to damage by disinfectant agents; and

        (V) have non-porous and washable floors or floor covering to enable regular disinfection.

      (iii) If the CACI is used in the compounding of high-risk hazardous preparations, the CACI shall be placed in an area or room with at least ISO 8 quality air so that high-risk powders, weighed in at least ISO-8 air quality conditions, are not exposed to lesser air quality prior to the completion of compounding and packaging of the high-risk preparation.

      (iv) Pharmacies that prepare a low volume of hazardous drugs, are not required to comply with the provisions of clauses (i) and (iii) of this subparagraph if the pharmacy uses a device that provides two tiers of containment (e.g., CACI that is located in a non-negative pressure room).

  (8) Additional Equipment and Supplies. Pharmacies compounding sterile preparations shall have the following equipment and supplies:

    (A) a calibrated system or device (i.e., thermometer) to monitor the temperature to ensure that proper storage requirements are met, if sterile preparations are stored in the refrigerator;

    (B) a calibrated system or device to monitor the temperature where bulk chemicals are stored;

    (C) a temperature-sensing mechanism suitably placed in the controlled temperature storage space to reflect accurately the true temperature;

    (D) if applicable, a Class A prescription balance, or analytical balance and weights. Such balance shall be properly maintained and subject to periodic inspection by the Texas State Board of Pharmacy;

    (E) equipment and utensils necessary for the proper compounding of sterile preparations. Such equipment and utensils used in the compounding process shall be:

      (i) of appropriate design, appropriate capacity, and be operated within designed operational limits;