and a sterile 10-milliliter syringe and 18-gauge needle combination is used to exchange two 5-milliliter aliquots of medium from one container to the other container in the pair. For example, after a 5-milliliter aliquot from the first container is added to the second container in the pair, the second container is agitated for 10 seconds, then a 5-milliliter aliquot is removed and returned to the first container in the pair. The first container is then agitated for 10 seconds, and the next 5-milliliter aliquot is transferred from it back to the second container in the pair. Following the two 5-milliliter aliquot exchanges in each pair of containers, a 5-milliliter aliquot of medium from each container is aseptically injected into a sealed, empty, sterile 10-milliliter clear vial, using a sterile 10-milliliter syringe and vented needle. Sterile adhesive seals are aseptically affixed to the rubber closures on the three filled vials. The vials are incubated within a range of 20 - 35 degrees Celsius for a minimum of 14 days. Failure is indicated by visible turbidity in the medium on or before 14 days. The media-fill test must include a positive-control sample.

      (iii) High risk level preparations.

        (I) Procedures for high-risk level compounded sterile preparations include all those for low-risk level compounded sterile preparations. In addition, a media-fill test that represents high-risk level compounding is performed twice a year by each person authorized to compound high-risk level compounded sterile preparations.

        (II) Example of a Media-Fill Test Procedure for Compounded Sterile Preparations Sterilized by Filtration. This test, or an equivalent test, is performed under conditions that closely simulate the most challenging or stressful conditions encountered when compounding high-risk level compounded sterile preparations. Note: Sterility tests for autoclaved compounded sterile preparations are not required unless they are prepared in batches of more than 25 units. This test is completed without interruption in the following sequence:

          (-a-) Dissolve 3 grams of non-sterile commercially available fluid culture media in 100 milliliters of non-bacteriostatic water to make a 3% non-sterile solution.

          (-b-) Draw 25 milliliters of the medium into each of three 30-milliliter sterile syringes. Transfer 5 milliliters from each syringe into separate sterile 10-milliliter vials. These vials are the positive controls to generate exponential microbial growth, which is indicated by visible turbidity upon incubation.

          (-c-) Under aseptic conditions and using aseptic techniques, affix a sterile 0.2-micron porosity filter unit and a 20-gauge needle to each syringe. Inject the next 10 milliliters from each syringe into three separate 10-milliliter sterile vials. Repeat the process for three more vials. Label all vials, affix sterile adhesive seals to the closure of the nine vials, and incubate them at 20 to 35 degrees Celsius for a minimum of 14 days. Inspect for microbial growth over 14 days as described in Chapter 797 Pharmaceutical Compounding--Sterile Preparations, of the USP/NF.

        (III) Filter Integrity Testing. Filters need to undergo testing to evaluate the integrity of filters used to sterilize high-risk preparations, such as Bubble Point Testing or comparable filter integrity testing. Such testing is not a replacement for sterility testing and shall not be interpreted as such. Such test shall be performed after a sterilization procedure on all filters used to sterilize each high-risk preparation or batch preparation and the results documented. The results should be compared with the filter manufacturer's specification for the specific filter used. If a filter fails the integrity test, the preparation or batch must be sterilized again using new unused filters.

    (B) Finished preparation release checks and tests.

      (i) All high-risk level compounded sterile preparations that are prepared in groups of more than 25 identical individual single-dose packages (such as ampules, bags, syringes, and vials), or in multiple dose vials for administration to multiple patients, or are exposed longer than 12 hours at 2 - 8 degrees Celsius and longer than six hours at warmer than 8 degrees Celsius before they are sterilized shall be tested to ensure they are sterile and do not contain excessive bacterial endotoxins as specified in Chapter 71, Sterility Tests of the USP/NF before being dispensed or administered.

      (ii) All compounded sterile preparations, except for sterile radiopharmaceuticals, that are intended to be solutions must be visually examined for the presence of particulate matter and not administered or dispensed when such matter is observed.

      (iii) The prescription drug and medication orders, written compounding procedure, preparation records, and expended materials used to make compounded sterile preparations at all contamination risk levels shall be inspected for accuracy of correct identities and amounts of ingredients, aseptic mixing and sterilization, packaging, labeling, and expected physical appearance before they are dispensed or administered.

      (iv) Written procedures for checking compounding accuracy shall be followed for every compounded sterile preparation during preparation, in accordance with pharmacy's policies and procedures, and immediately prior to release, including label accuracy and the accuracy of the addition of all drug products or ingredients used to prepare the finished preparation and their volumes or quantities. A pharmacist shall ensure that components used in compounding are accurately weighed, measured, or subdivided as appropriate to conform to the formula being prepared.

    (C) Environmental Testing.

      (i) Viable and nonviable environmental sampling testing. Environmental sampling shall occur, at a minimum, every six months as part of a comprehensive quality management program and under any of the following conditions:

        (I) as part of the commissioning and certification of new facilities and equipment;

        (II) following any servicing of facilities and equipment;

        (III) as part of the re-certification of facilities and equipment;

        (IV) in response to identified problems with end products or staff technique; or

        (V) in response to issues with compounded sterile preparations, observed compounding personnel work practices, or patient-related infections (where the compounded sterile preparation is being considered as a potential source of the infection).

      (ii) Total particle counts. Certification that each ISO classified area (e.g., ISO Class 5, 7, and 8), is within established guidelines shall be performed no less than every six months and whenever the equipment is relocated or the physical structure of the buffer area or ante-area has been altered. All certification records shall be maintained and reviewed to ensure that the controlled environments comply with the proper air cleanliness, room pressures, and air changes per hour. These certification records must include acceptance criteria and be made available upon inspection by the Board. Testing shall be performed by qualified operators using current, state-of-the-art equipment, with results of the following:

        (I) ISO Class 5 - not more than 3520 particles 0.5 micrometer and larger size per cubic meter of air;

        (II) ISO Class 7 - not more than 352,000 particles of 0.5 micrometer and larger size per cubic meter of air for any buffer area; and

        (III) ISO Class 8 - not more than 3,520,000 particles of 0.5 micrometer and larger size per cubic meter of air for any ante-area.

      (iii) Pressure differential monitoring. A pressure gauge or velocity meter shall be installed to monitor the pressure differential or airflow between the buffer area and the ante-area and between the ante-area and the general environment outside the compounding area. The results shall be reviewed and documented on a log at least every work shift (minimum frequency shall be at least daily) or by a continuous recording device. The pressure between the ISO Class 7 or ISO Class 8 and the general pharmacy area shall not be less than 0.02 inch water column.

      (iv) Sampling plan. An appropriate environmental sampling plan shall be developed for airborne viable particles based on a risk assessment of compounding activities performed. Selected sampling sites shall include locations within each ISO Class 5 environment and in the ISO Class 7 and 8 areas and in the segregated compounding areas at greatest risk of contamination. The plan shall include sample location, method of collection, frequency of sampling, volume of air sampled, and time of day as related to activity in the compounding area and action levels.

      (v) Viable air sampling. Evaluation of airborne microorganisms using volumetric collection methods in the controlled air environments shall be performed by properly trained individuals for all compounding risk levels. For low-, medium-, and high-risk level compounding, air sampling shall be performed at locations that are prone to contamination during compounding activities and during other activities such as staging, labeling, gowning, and cleaning. Locations shall include zones of air backwash turbulence Cont'd...