(a) A permit application for a stationary commercial
solid oil and gas waste recycling facility shall include the layout
and design of the facility by including a plat drawn to scale with
north arrow to top of the map showing the location and information
on the design and size of all receiving, processing, and storage areas
and all equipment (e.g., pug mill), tanks, silos, monitor wells, dikes,
fences, and access roads.
(b) A permit application for a stationary commercial
solid oil and gas waste recycling facility also shall include:
(1) a description of the type and thickness of liners
(e.g., fiberglass, steel concrete), if any, for all tanks, silos,
pits, and storage areas/cells;
(2) for storage areas where tanks and/or liners are
not used, credible engineering and/or geologic information demonstrating
that tanks or liners are not necessary for the protection of surface
and subsurface water;
(3) a map view and two perpendicular cross-sectional
views of pits and/or storage areas/cells to be constructed, showing
the bottom, sides, and dikes, showing the dimensions of each;
(4) a plan to control and manage storm water runoff
and to retain incoming wastes during wet weather, including the location
and dimensions of dikes and/or storage basins that would collect storm
water from the facility during a 25-year, 24-hour maximum rainfall
event, and all calculations made to determine the required capacity
and design; and
(5) a plan for the installation of monitoring wells
at the facility.
|