RULE §535.232Standards of Practice: Minimum Inspection Requirements for Appliances
Repealed Date:01/01/2014

(a) Dishwasher. The inspector shall report as Deficient:

  (1) inoperative unit(s);

  (2) rust on the interior of the cabinet or components;

  (3) failure to drain properly;

  (4) the presence of active water leaks; and

  (5) deficiencies in the:

    (A) door gasket;

    (B) control and control panels;

    (C) dish racks;

    (D) rollers;

    (E) spray arms;

    (F) operation of the soap dispenser;

    (G) door springs;

    (H) dryer element;

    (I) door latch and door disconnect;

    (J) rinse cap;

    (K) secure mounting of the unit; and

    (L) backflow prevention.

(b) Food waste disposer. The inspector shall report as Deficient:

  (1) inoperative unit(s);

  (2) unusual sounds or vibration level;

  (3) the presence of active water leaks; and

  (4) deficiencies in the:

    (A) splash guard;

    (B) grinding components;

    (C) exterior casing; and

    (D) secure mounting of the unit.

(c) Range exhaust vent. The inspector shall report as Deficient:

  (1) inoperative unit(s);

  (2) a vent pipe that does not terminate outside the structure, if the unit is not of a re-circulating type or configuration;

  (3) inadequate vent pipe material;

  (4) unusual sounds or vibration levels from the blower fan(s);

  (5) blower(s) that do not operate at all speeds; and

  (6) deficiencies in the:

    (A) filter;

    (B) vent pipe;

    (C) light and lens;

    (D) secure mounting of the unit; and

    (E) switches.

(d) Electric or gas ranges, cooktops, and ovens. The inspector shall report as Deficient:

  (1) inoperative unit(s);

  (2) the lack of a gas shut-off valve;

  (3) gas leaks; and

  (4) deficiencies in the:

    (A) controls and control panels;

    (B) thermostat(s) sensor support;

    (C) glass panels;

    (D) door gasket(s), hinges, springs, closure, and handles;

    (E) door latch;

    (F) heating elements or burners;

    (G) thermostat accuracy (within 25 degrees at a setting of 350°F);

    (H) drip pans;

    (I) lights and lenses;

    (J) clearance to combustible material;

    (K) anti-tip device;

    (L) gas shut-off valve(s) and location(s);

    (M) gas connector materials and connections; and

    (N) secure mounting of the unit.

(e) Microwave oven. The inspector shall:

  (1) inspect built-in units; and

  (2) report as Deficient:

    (A) inoperative unit(s); and

    (B) deficiencies in the:

      (i) controls and control panels;

      (ii) handles;

      (iii) the turn table;

      (iv) interior surfaces;

      (v) door and door seal;

      (vi) glass panels;

      (vii) lights and lenses;

      (viii) secure mounting of the unit; and

      (ix) operation, as determined by heating a container of water or with other means of testing.

(f) Trash compactor. The inspector shall report as Deficient:

  (1) inoperative unit(s);

  (2) unusual sounds or vibration levels; and

  (3) deficiencies in the secure mounting of the unit.

(g) Mechanical exhaust vents and bathroom heaters. The inspector shall report as Deficient:

  (1) inoperative unit(s);

  (2) unusual sounds, speed, and vibration levels;

  (3) vent pipes that do not terminate outside the structure;

  (4) a gas heater that is not vented to the exterior of the structure; and

  (5) the lack of an exhaust ventilator in required areas.

(h) Garage door operators. The inspector shall report as Deficient:

  (1) inoperative unit(s);

  (2) door locks or side ropes that have not been removed or disabled; and

  (3) deficiencies in:

    (A) installation;

    (B) condition and operation of the garage door operator;

    (C) automatic reversal during the closing cycle;

    (D) electronic sensors;

    (E) the control button; and

    (F) the emergency release components.

(i) Doorbell and chimes. The inspector shall report as Deficient:

  (1) inoperable unit(s); and

  (2) deficiencies in components.

(j) Dryer vents. The inspector shall report as Deficient:

  (1) improper routing and length of vent pipe;

  (2) inadequate vent pipe material;

  (3) improper termination;

  (4) the lack of a dryer vent system when provisions are present for a dryer; and

  (5) damaged or missing exterior cover.

(k) Specific limitations for appliances. The inspector is not required to:

  (1) operate or determine the condition of other auxiliary components of inspected items;

  (2) test for microwave oven radiation leaks;

  (3) inspect self-cleaning functions;

  (4) test trash compactor ram pressure; or

  (5) determine the adequacy of venting systems.