<<Prev Rule

Texas Administrative Code

Next Rule>>
TITLE 16ECONOMIC REGULATION
PART 2PUBLIC UTILITY COMMISSION OF TEXAS
CHAPTER 25SUBSTANTIVE RULES APPLICABLE TO ELECTRIC SERVICE PROVIDERS
SUBCHAPTER HELECTRICAL PLANNING
DIVISION 2ENERGY EFFICIENCY AND CUSTOMER-OWNED RESOURCES
RULE §25.181Energy Efficiency Goal

(a) Purpose. The purpose of this section is to ensure that:

  (1) electric utilities administer energy efficiency incentive programs in a market-neutral, nondiscriminatory manner and do not offer competitive services, except as permitted in §25.343 of this title (relating to Competitive Energy Services) or this section;

  (2) all customers, in all eligible customer classes and all areas of an electric utility's service area, have a choice of and access to the utility's portfolio of energy efficiency programs that allow each customer to reduce energy consumption, summer and winter peak demand, or energy costs; and

  (3) each electric utility annually provides, through market-based standard offer programs, targeted market-transformation programs, or utility self-delivered programs, incentives sufficient for residential and commercial customers, retail electric providers, and energy efficiency service providers to acquire additional cost-effective energy efficiency, subject to EECRF caps established in §25.182(d)(7) of this title (relating to Energy Efficiency Cost Recovery Factor), for the utility to achieve the goals in subsection (e) of this section.

(b) Application. This section applies to electric utilities and the Electric Reliability Council of Texas, Inc. (ERCOT).

(c) Definitions. The following terms, when used in this section and in §25.182 of this title, shall have the following meanings unless the context indicates otherwise:

  (1) Affiliate --

    (A) A person who directly or indirectly owns or holds at least 5.0% of the voting securities of an energy efficiency service provider;

    (B) A person in a chain of successive ownership of at least 5.0% of the voting securities of an energy efficiency service provider;

    (C) A corporation that has at least 5.0% of its voting securities owned or controlled, directly or indirectly, by an energy efficiency service provider;

    (D) A corporation that has at least 5.0% of its voting securities owned or controlled, directly or indirectly, by:

      (i) a person who directly or indirectly owns or controls at least 5.0% of the voting securities of an energy efficiency service provider; or

      (ii) a person in a chain of successive ownership of at least 5.0% of the voting securities of an energy efficiency service provider; or

    (E) A person who is an officer or director of an energy efficiency service provider or of a corporation in a chain of successive ownership of at least 5.0% of the voting securities of an energy efficiency service provider;

    (F) A person who actually exercises substantial influence or control over the policies and actions of an energy efficiency service provider;

    (G) A person over which the energy efficiency service provider exercises the control described in subparagraph (F) of this paragraph;

    (H) A person who exercises common control over an energy efficiency service provider, where "exercising common control over an energy efficiency service provider" means having the power, either directly or indirectly, to direct or cause the direction of the management or policies of an energy efficiency service provider, without regard to whether that power is established through ownership or voting of securities or any other direct or indirect means; or

    (I) A person who, together with one or more persons with whom the person is related by ownership, marriage or blood relationship, or by action in concert, actually exercises substantial influence over the policies and actions of an energy efficiency service provider even though neither person may qualify as an affiliate individually.

  (2) Baseline--A relevant condition that would have existed in the absence of the energy efficiency project or program being implemented, including energy consumption that would have occurred. Baselines are used to calculate program-related demand and energy savings. Baselines can be defined as either project-specific baselines or performance standard baselines (e.g., building codes).

  (3) Claimed savings--Values reported by an electric utility after the energy efficiency activities have been completed, but prior to the time an independent, third-party evaluation of the savings is performed. As with projected savings estimates, these values may utilize results of prior evaluations and/or values in technical reference manuals. However, they are adjusted from projected savings estimates by correcting for any known data errors and actual installation rates and may also be adjusted with revised values for factors such as per-unit savings values, operating hours, and savings persistence rates. Can be indicated as first year, annual demand or energy savings, and/or lifetime energy or demand savings values. Can be indicated as gross savings and/or net savings values.

  (4) Commercial customer--A non-residential customer taking service at a point of delivery at a distribution voltage under an electric utility's tariff during the prior program year or a non-profit customer or government entity, including an educational institution. For purposes of this section, each point of delivery shall be considered a separate customer.

  (5) Competitive energy efficiency services--Energy efficiency services that are defined as competitive under §25.341 of this title (relating to Definitions).

  (6) Conservation load factor--The ratio of the annual energy savings goal, in kilowatt hours (kWh), to the peak demand goal for the year, measured in kilowatts (kW) and multiplied by the number of hours in the year.

  (7) Deemed savings calculation--An industry-wide engineering algorithm used to calculate energy and/or demand savings of the installed energy efficiency measure that has been developed from common practice that is widely considered acceptable for the measure and purpose, and is applicable to the situation being evaluated. May include stipulated assumptions for one or more parameters in the algorithm, but typically requires some data associated with actual installed measure. An electric utility may use the calculation with documented measure-specific assumptions, instead of energy and peak demand savings determined through measurement and verification activities or the use of deemed savings.

  (8) Deemed savings value--An estimate of energy or demand savings for a single unit of an installed energy efficiency measure that has been developed from data sources and analytical methods that are widely considered acceptable for the measure and purpose, and is applicable to the situation being evaluated. An electric utility may use deemed savings values instead of energy and peak demand savings determined through measurement and verification activities.

  (9) Demand--The rate at which electric energy is used at a given instant, or averaged over a designated period, usually expressed in kW or megawatts (MW).

  (10) Demand savings--A quantifiable reduction in demand.

  (11) Eligible customers--Residential and commercial customers. In addition, to the extent that they meet the criteria for participation in load management standard offer programs developed for industrial customers and implemented prior to May 1, 2007, industrial customers are eligible customers solely for the purpose of participating in such programs.

  (12) Energy efficiency--Improvements in the use of electricity that are achieved through customer facility or customer equipment improvements, devices, processes, or behavioral or operational changes that produce reductions in demand or energy consumption with the same or higher level of end-use service and that do not materially degrade existing levels of comfort, convenience, and productivity.

  (13) Energy Efficiency Cost Recovery Factor (EECRF)--An electric tariff provision, compliant with §25.182 of this title, ensuring timely and reasonable cost recovery for utility expenditures made to satisfy the goal of PURA §39.905 that provide for a portfolio of cost-effective energy efficiency programs under this section.

  (14) Energy efficiency measures--Equipment, materials, and practices, including practices that result in behavioral or operational changes, implemented at a customer's site on the customer's side of the meter that result in a reduction at the customer level and/or on the utility's system in electric energy consumption, measured in kWh, or peak demand, measured in kW, or both. These measures may include thermal energy storage and removal of an inefficient appliance so long as the customer need satisfied by the appliance is still met.

  (15) Energy efficiency program--The aggregate of the energy efficiency activities carried out by an electric utility under this section or a set of energy efficiency projects carried out by an electric utility under the same name and operating rules.

  (16) Energy efficiency project--An energy efficiency measure or combination of measures undertaken in accordance with a standard offer, market transformation program, or self-delivered program.

Cont'd...