<<Prev Rule

Texas Administrative Code

Next Rule>>
TITLE 30ENVIRONMENTAL QUALITY
PART 1TEXAS COMMISSION ON ENVIRONMENTAL QUALITY
CHAPTER 112CONTROL OF AIR POLLUTION FROM SULFUR COMPOUNDS
SUBCHAPTER ACONTROL OF SULPHUR DIOXIDE
RULE §112.7Allowable Emission Rates--Sulfur Recovery Plant

(a) No person may cause, suffer, allow, or permit emissions of sulfur dioxide (SO[sub]2[/sub]) from any sulfur recovery plant to exceed the emission limits specified for stack effluent flow rates less than or equal to 4,000 standard cubic feet per minute (scfm) as determined by the equation:

Attached Graphic (b) If a source has an effective stack height less than the standard effective stack height determined for stack effluent rates less than or equal to 4,000 scfm by the equation:

Attached Graphic

then, the allowable emission limit in subsection (a) of this section must be reduced by multiplying it by the short-stack reduction factor.


Source Note: The provisions of this §112.7 adopted to be effective October 23, 1992, 17 TexReg 7085.

Link to Texas Secretary of State Home Page | link to Texas Register home page | link to Texas Administrative Code home page | link to Open Meetings home page