RULE §115.468Monitoring and Recordkeeping Requirements

(a) Monitoring requirements. The following monitoring requirements apply to the owner or operator of a solvent cleaning operation subject to this division that uses a vapor control system in accordance with §115.463(b) of this title (relating to Control Requirements). The owner or operator shall install and maintain monitors to accurately measure and record operational parameters of all required control devices, as necessary, to ensure the proper functioning of those devices in accordance with design specifications, including:

  (1) continuous monitoring of the exhaust gas temperature immediately downstream of direct-flame incinerators or the gas temperature immediately upstream and downstream of any catalyst bed;

  (2) the total amount of volatile organic compounds (VOC) recovered by carbon adsorption or other solvent recovery systems during a calendar month;

  (3) continuous monitoring of carbon adsorption bed exhaust; and

  (4) appropriate operating parameters for vapor control systems other than those specified in paragraphs (1) - (3) of this subsection.

(b) Recordkeeping requirements. The following recordkeeping requirements apply to the owner or operator of a solvent cleaning operation subject to this division.

  (1) The owner or operator shall maintain records of the testing data, the material safety data sheet, or documentation of the standard reference texts used to determine the true vapor pressure of each VOC component, in accordance with the requirements in §115.465(1) of this title (relating to Approved Test Methods and Testing Requirements). The concentration of all VOC used to prepare the cleaning solution and, if diluted prior to use, the proportions that each of these materials is used must be recorded. Records must be sufficient to demonstrate continuous compliance with the VOC limits in §115.463(a) of this title.

  (2) The owner or operator claiming an exemption in §115.461 of this title (relating to Exemptions) shall maintain records sufficient to demonstrate continuous compliance with the applicable exemption criteria.

  (3) The owner or operator claiming exemption from this division in accordance with §115.461(c) of this title shall maintain records indicating the applicable division the process or operation is subject to as specified in §115.461(c)(1) of this title and the control requirements or emission specifications used to control the VOC emissions from the solvent cleaning operation as specified in §115.461(c)(2) of this title. The owner or operator shall also comply with the applicable recordkeeping requirements from the division the process or operation is subject to sufficient to demonstrate that the VOC emissions from the solvent cleaning operation are controlled in accordance with the control requirements or emission specifications of that division.

  (4) The owner or operator shall maintain records of any testing conducted in accordance with the provisions specified in §115.465(2) - (4) of this title.

  (5) Records must be maintained a minimum of two years and be made available upon request to authorized representatives of the executive director, the United States Environmental Protection Agency, or any local air pollution agency with jurisdiction.


Source Note: The provisions of this §115.468 adopted to be effective December 29, 2011, 36 TexReg 8897