RULE §259.748Ceilings

Ceilings within inmate housing areas shall be constructed of a minimum 4" thick concrete plank reinforced with #4 bars 8" on center each way or a minimum 10 gauge steel plate. Innovative design concepts are encouraged and comparable materials and methods approved by the Commission may be utilized for ceiling construction.


Source Note: The provisions of this §259.748 adopted to be effective April 4, 1999, 24 TexReg 2355