(B) deficiencies in steps, stairways, landings, guardrails,
and handrails.
(2) The inspector is not required to exhaustively measure
every stairway component.
(i) Fireplaces and chimneys.
(1) The inspector shall report as Deficient:
(A) built-up creosote in accessible areas of the firebox
and flue;
(B) the presence of combustible materials in near proximity
to the firebox opening;
(C) the absence of fireblocking at the attic penetration
of the chimney flue, where accessible; and
(D) deficiencies in the:
(i) damper;
(ii) lintel, hearth, hearth extension, and firebox;
(iii) gas valve and location;
(iv) circulating fan;
(v) combustion air vents; and
(vi) chimney structure, termination, coping, crown,
caps, and spark arrestor.
(2) The inspector is not required to:
(A) verify the integrity of the flue;
(B) perform a chimney smoke test; or
(C) determine the adequacy of the draft.
(j) Porches, Balconies, Decks, and Carports.
(1) The inspector shall:
(A) inspect:
(i) attached balconies, carports, and porches;
(ii) abutting porches, decks, and balconies that are
used for ingress and egress; and
(B) report as Deficient:
(i) on decks 30 inches or higher above the adjacent
grade, spacings between intermediate balusters, spindles, or rails
that permit passage of an object greater than four inches in diameter;
and
(ii) deficiencies in accessible components.
(2) The inspector is not required to:
(A) exhaustively measure every porch, balcony, deck,
or attached carport components; or
(B) enter any area where headroom is less than 18 inches
or the access opening is less than 24 inches wide and 18 inches high.
|