(3) project the volume of traffic expected to be generated by the facility on the access roads within one mile of the proposed facility; (4) submit documentation of coordination of all designs of proposed public roadway improvements such as turning lanes, storage lanes, etc., associated with site entrances with the agency exercising maintenance responsibility of the public roadway involved. In addition, the owner or operator shall submit documentation of coordination with the Texas Department of Transportation for traffic and location restrictions; and (5) for landfill units and landfill mining operations, analyze the impact of the facility upon airports in accordance with §330.545 of this title (relating to Airport Safety). The owner or operator shall submit documentation of coordination with the Federal Aviation Administration for compliance with airport location restrictions. (j) General geology and soils statement. The reports prepared under this subsection must meet the following requirements: (1) discuss in general terms the geology and soils of the proposed site; (2) for landfills, identify and provide data on fault areas located within the proposed site in accordance with §330.555 of this title (relating to Fault Areas); (3) for landfills, identify and provide data on seismic impact zones in accordance with §330.557 of this title (relating to Seismic Impact Zones); and (4) for landfills, identify and provide data on unstable areas in accordance with §330.559 of this title (relating to Unstable Areas). (k) Groundwater and surface water. The owner or operator shall submit: (1) data about the site-specific groundwater conditions at and near the site; (2) data on surface water at and near the site; and (3) information demonstrating how the municipal solid waste facility will comply with applicable Texas Pollutant Discharge Elimination System (TPDES) storm water permitting requirements and the Clean Water Act, §402, as amended. This information may include, but is not limited to: (A) a certification statement indicating the owner/operator will obtain the appropriate TPDES permit coverage when required; or (B) a copy of the permit number for coverage under an individual wastewater permit. (l) Abandoned oil and water wells. (1) The owner or operator shall identify the location of any and all existing or abandoned water wells situated within the facility. Water wells necessary for supply for operations at the landfill may remain in use as long as the wells are located outside of the groundwater monitoring well network, and are not subject to impact from landfill operations. Water wells that will be used for supply at the landfill that are located inside of the groundwater monitoring network, but outside the landfill unit boundary, may be used if identified and approved in the facility permit. For all other facility water wells, the owner or operator shall provide, within 30 days prior to construction, the executive director with written certification that all such wells have been capped, plugged, and closed in accordance with all applicable rules and regulations of the commission or other state agency. (2) The owner or operator shall identify the location of any and all existing or abandoned on-site crude oil or natural gas wells, or other wells associated with mineral recovery that are under the jurisdiction of the Railroad Commission of Texas. The owner or operator shall provide the executive director with written certification that these wells have been properly capped, plugged, and closed in accordance with all applicable rules and regulations of the Railroad Commission of Texas at the time of application. Producing crude oil or natural gas wells that do not affect or hamper landfill operations may remain in their current state, if identified in the permit for the facility. (m) Floodplains and wetlands statement. The floodplains and wetlands statement must: (1) provide data on floodplains in accordance with Chapter 301, Subchapter C of this title (relating to Approval of Levees and Other Improvements); (2) include a wetlands determination under applicable federal, state, and local laws and discuss wetlands in accordance with §330.553 of this title (relating to Wetlands). For the purpose of this subsection, demonstration can be made by providing evidence that the facility has a Corps of Engineers permit for the use of any wetlands area; and (3) identify wetlands located within the facility boundary. (n) Endangered or threatened species. (1) The owner or operator shall consider the impact of a solid waste disposal facility upon endangered or threatened species. The facility and the operation of the facility shall not result in the destruction or adverse modification of the critical habitat of endangered or threatened species, or cause or contribute to the taking of any endangered or threatened species. (2) For landfill applications, the owner or operator shall submit Endangered Species Act compliance demonstrations as required under state and federal laws and determine whether the facility is in the range of endangered or threatened species. If the facility is located in the range of endangered or threatened species, the owner or operator shall have a biological assessment prepared by a qualified biologist in accordance with standard procedures of the United States Fish and Wildlife Service and the Texas Parks and Wildlife Department to determine the effect of the facility on the endangered or threatened species. Where a previous biological assessment has been made for another project in the general vicinity, a copy of that assessment may be submitted for evaluation. The United States Fish and Wildlife Service and the Texas Parks and Wildlife Department shall be contacted for locations and specific data relating to endangered and threatened species in Texas. (o) Texas Historical Commission review. The owner or operator shall submit a review letter from the Texas Historical Commission documenting compliance with the Natural Resources Code, Chapter 191, Texas Antiquities Code. (p) Council of governments and local government review request. The owner or operator shall submit documentation that Parts I and II of the application were submitted for review to the applicable council of governments for compliance with regional solid waste plans. The owner or operator shall also submit documentation that a review letter was requested from any local governments as appropriate for compliance with local solid waste plans. A review letter is not a prerequisite to a final determination on a permit or registration application. |