(A) Operational parameters of any emission control
device installed to comply with the requirements in §115.442(b)(5)
of this title must be continuously measured and recorded. Monitors
must be installed, calibrated, maintained, and operated according
to the manufacturer's instructions. Temperature monitors must be equipped
with a continuous recorder and have an accuracy of ±0.5 degrees
Fahrenheit or ±1.0% of the temperature being monitored, whichever
is less stringent. Measuring and recording the operational parameters
of the control device at least once every 15 minutes is sufficient
to demonstrate compliance with this subparagraph. Records must be
sufficient to demonstrate proper functioning of the device to design
specifications and must include:
(i) the exhaust gas temperature of direct-flame incinerators
and/or the gas temperature immediately upstream and downstream of
any catalyst bed;
(ii) the total amount of VOC recovered by a carbon
adsorption system or other solvent recovery system per calendar month;
and
(iii) the exhaust gas VOC concentration of any carbon
adsorption system to determine if breakthrough has occurred.
(B) An air flow direction measuring device must be
used to demonstrate the dryer meets the 100% capture efficiency required
in §115.442(b)(5) of this title.
(6) The owner or operator of an offset lithographic
printing press shall maintain the results of any tests conducted using
the approved test methods in §115.445 of this title.
(7) The owner or operator of an offset lithographic
printing press shall maintain all records for at least two years and
make such records available upon request to authorized representatives
of the executive director, the United States Environmental Protection
Agency, or any local air pollution agency with jurisdiction.
|
Source Note: The provisions of this §115.446 adopted to be effective December 3, 1993, 18 TexReg 8538; amended to be effective May 27, 1994, 19 TexReg 3703; amended to be effective March 7, 1996, 21 TexReg 1548; amended to be effective May 22, 1997, 22 TexReg 4213; amended to be effective March 21, 1999, 24 TexReg 1777; amended to be effective May 16, 2002, 27 TexReg 4113; amended to be effective April 1, 2010, 35 TexReg 2579; amended to be effective June 25, 2015, 40 TexReg 3907 |