<<Prev Rule

Texas Administrative Code

Next Rule>>
TITLE 16ECONOMIC REGULATION
PART 4TEXAS DEPARTMENT OF LICENSING AND REGULATION
CHAPTER 76WATER WELL DRILLERS AND WATER WELL PUMP INSTALLERS
RULE §76.100Technical Requirements--Locations and Standards of Completion for Wells

  (5) The well casing of a temporary monitoring well shall have a locking cap and the annular space shall be sealed from zero (0) to one (1) foot below ground level with an impervious bentonite or similar material; and after forty-eight (48) hours, the well must be completed in accordance with this section or plugged in accordance with §76.104.

  (6) The annular space of a closed loop geothermal well used to circulate water or other fluids shall be backfilled to the total depth with impervious bentonite or similar material, closed loop injection well where there is no water or only one zone of water is encountered you may use sand, gravel or drill cuttings to back fill up to ten (10) feet from the surface. The top ten (10) feet shall be filled with impervious bentonite or similar materials and shall meet the standards pursuant to Texas Commission on Environmental Quality 30 TAC Chapter 331.

(g) Alternative Surface Completion. In wells where a steel or PVC sleeve is used:

  (1) The steel sleeve shall be a minimum of 3/16 inches in thickness and shall be a minimum of twenty-four (24) inches in length. The plastic sleeve shall be a minimum of Schedule 80 sun resistant or SDR 17 sun resistant and be twenty-four (24) inches in length, and either sleeve used shall extend twelve (12) inches into the cement, except when steel casing or a pitless adapter as described in paragraph (2) is used. The casing shall extend to a minimum of twelve (12) inches above the land surface, and the steel/plastic sleeve's inside diameter shall be two (2) inches larger in diameter than the outside diameter of the plastic casing being used and filled entirely with cement; or

  (2) A slab or block as described in subsection (f) is required above the cement slurry except when steel casing or a pitless adapter is used. Pitless adapters may be used in such wells, provided that:

    (A) the adapter is welded to the casing or fitted with another suitably effective seal;

    (B) the annular space between the borehole and the casing is filled with cement to a depth not less than twenty (20) feet below the adapter connection; and

    (C) in lieu of cement, the annular space may be filled with a solid column of granular sodium bentonite to a depth of not less than twenty (20) feet below the adapter connection.

(h) Unless waived in writing by the landowner, a new, repaired or reconditioned well or pump installation or repair on a well that is used to supply water for human consumption, shall be properly disinfected.


Source Note: The provisions of this §76.100 adopted to be effective September 15, 2014, 39 TexReg 7090; amended to be effective January 1, 2016, 40 TexReg 8756; amended to be effective April 1, 2018, 43 TexReg 1635

Previous Page

Link to Texas Secretary of State Home Page | link to Texas Register home page | link to Texas Administrative Code home page | link to Open Meetings home page