  (1) Authority to transfer possession or control by the manufacturer, processor, or producer of any equipment, device, commodity, or other product containing source material, byproduct material, or naturally occurring and accelerator-produced radioactive material (NARM) whose subsequent possession, use, transfer, and disposal by all other persons are exempted from regulatory requirements may be obtained only from the United States Nuclear Regulatory Commission (NRC), Washington, DC 20555 in accordance with Title 10, Code of Federal Regulations (CFR), §32.18.

  (2) Licenses issued in accordance with this subsection do not authorize the following:

    (A) combining of exempt quantities of radioactive material in a single device;

    (B) any program advising persons to combine exempt quantity sources and providing devices for them to do so; and

    (C) the possession and use of combined exempt sources, in a single unregistered device, by persons exempt from licensing in accordance with §289.251(e)(2) of this title.

(k) Specific licenses for incorporation of byproduct material or NARM into gas and aerosol detectors. A specific license authorizing the incorporation of byproduct material or NARM into gas and aerosol detectors to be distributed to persons exempt from this chapter shall be issued only by the NRC in accordance with Title 10, CFR, §32.26.

(l) Specific licenses for the manufacture and commercial distribution of devices to persons generally licensed in accordance with §289.251(f)(4)(H) of this title.

  (1) In addition to the requirements in subsection (e) of this section, a specific license to manufacture or commercially distribute devices containing radioactive material to persons generally licensed in accordance with §289.251(f)(4)(H) of this title or equivalent requirements of the NRC or any agreement state will be issued if the department approves the following information submitted by the applicant:

    (A) the design, manufacture, prototype testing, quality control, labels, proposed uses, installation, servicing, leak testing, operating and safety instructions, and potential hazards of the device to provide reasonable assurance that:

      (i) the device can be safely operated by persons not having training in radiological protection;

      (ii) under ordinary conditions of handling, storage, and use of the device, the radioactive material contained in the device will not be released or inadvertently removed from the device, and it is unlikely that any person will receive in any period of one year a dose in excess of ten percent of the limits specified in §289.202(f) of this title; and

      (iii) under accident conditions (such as fire and explosion) associated with handling, storage, and use of the device, it is unlikely that any person would receive an external radiation dose or dose commitment in excess of the following organ doses:

        (I) 15 rems to the whole body; head and trunk; active blood-forming organs; gonads; or lens of eye;

        (II) 200 rems to the hands and forearms; feet and ankles; localized areas of skin averaged over areas no larger than 1 square centimeter (cm2 ); or

        (III) 50 rems to other organs;

    (B) procedures for disposition of unused or unwanted radioactive material;

    (C) each device bears a durable, legible, clearly visible label or labels approved by the department that contain the following in a clearly identified and separate statement:

      (i) instructions and precautions necessary to assure safe installation, operation, and servicing of the device (documents such as operating and service manuals may be identified in the label and used to provide this information);

      (ii) the requirement, or lack of requirement, for leak testing, or for testing any "on-off" mechanism and indicator, including the maximum time interval for such testing, and the identification of radioactive material by isotope, quantity of radioactivity, and date of determination of the quantity; and

      (iii) the information called for in one of the following statements, as appropriate, in the same or substantially similar form:

        (I) For radioactive materials other than NARM, the following statement is appropriate:

Attached Graphic

        (II) For NARM, the following statement is appropriate:

Attached Graphic

        (III) The model and serial number and name of manufacturer or distributor may be omitted from this label provided they are elsewhere stated in labeling affixed to the device.

    (D) Each device having a separable source housing that provides the primary shielding for the source also bears, on the source housing, a durable label containing the device model number and serial numbers, the isotope and quantity, the words, "Caution-Radioactive Material," the radiation symbol described in §289.202(z) of this title, and the name of the manufacturer or initial distributor.

    (E) Each device meeting the criteria of §289.251(g)(1) of this title, bears a permanent (for example, embossed, etched, stamped, or engraved) label affixed to the source housing if separable, or the device if the source housing is not separable, that includes the words, "Caution-Radioactive Material," and, if practicable, the radiation symbol described in §289.202(z) of this title.

    (F) The device has been registered in the Sealed Source and Device Registry.

  (2) In the event the applicant desires that the device be required to be tested at intervals longer than 6 months, either for proper operation of the "on-off" mechanism and indicator, if any, or for leakage of radioactive material, or for both, the applicant shall include in the application sufficient information to demonstrate that the longer interval is justified by performance characteristics of the device or similar devices and by design features that have a significant bearing on the probability or consequences of radioactive material leakage from the device or failure of the "on-off" mechanism and indicator. In determining the acceptable interval for the test for radioactive material leakage, the department will consider information that includes the following:

    (A) primary containment (sealed source capsule);

    (B) protection of primary containment;

    (C) method of sealing containment;

    (D) containment construction materials;

    (E) form of contained radioactive material;

    (F) maximum temperature withstood during prototype tests;

    (G) maximum pressure withstood during prototype tests;

    (H) maximum quantity of contained radioactive material;

    (I) radiotoxicity of contained radioactive material; and

    (J) operating experience with identical devices or similarly designed and constructed devices.

  (3) In the event the applicant desires that the general licensee in accordance with §289.251(f)(4)(H) of this title or in accordance with equivalent regulations of the NRC or any agreement state, be authorized to mount the device, collect the sample to be analyzed by a specific licensee for radioactive material leakage, perform maintenance of the device consisting of replacement of labels, rust and corrosion prevention, and for fixed gauges, repair and maintenance of sealed source holder mounting brackets, test the "on-off" mechanism and indicator, or remove the device from installation, the applicant shall include in the application written instructions to be followed by the general licensee, estimated annual doses associated with such activity or activities, and bases for such estimates. The submitted information shall demonstrate that performance of such activity or activities by an individual untrained in radiological protection, in addition to other handling, storage, and use of devices in accordance with the general license, is unlikely to cause that individual to receive an annual dose in excess of ten percent of the limits specified in §289.202(f) of this title.

  (4) Before the device may be transferred, each person licensed in accordance with this subsection to commercially distribute devices to generally licensed persons shall furnish:

    (A) a copy of the general license in §289.251(f)(4)(H) of this title to each person to whom the licensee directly commercially distributes radioactive material in a device for use in accordance with the general license in §289.251(f)(4)(H) of this title;

    (B) a copy of the general license in the NRC's or any agreement state's regulation equivalent to §289.251(f)(4)(H) of this title, or alternatively, a copy of the general license in §289.251(f)(4)(H) of this title to each person to whom the licensee directly commercially distributes radioactive material in a device for use in accordance with the general license of the NRC or any agreement state. If certain requirements of the regulations do not apply to the particular device, Cont'd...