<<Prev Rule

Texas Administrative Code

Next Rule>>
TITLE 30ENVIRONMENTAL QUALITY
PART 1TEXAS COMMISSION ON ENVIRONMENTAL QUALITY
CHAPTER 285ON-SITE SEWAGE FACILITIES
SUBCHAPTER HDISPOSAL OF GRAYWATER
RULE §285.81Requirements and Conditions for Potentially Reducing the Size of an OSSF Disposal System for a Single Family Residence with a Graywater Reuse System or a Combined Reuse System

(a) Graywater reuse systems and combined reuse systems are authorized in Chapter 210, Subchapter F of this title (relating to Use of Graywater and Alternative Onsite Water) without a permit, without the submission of planning materials, and without meeting the requirements and conditions of this section. However, a homeowner requesting an on-site sewage facility (OSSF) disposal system smaller than required in §285.33 of this title (relating to Criteria for Effluent Disposal Systems) must obtain a permit and meet the requirements and conditions of this section. Additionally, the potential reduction of the OSSF disposal system in this section only applies to single family residence with a graywater reuse or a combined reuse system. OSSF disposal systems for non-single family residences with a graywater reuse or a combined reuse system shall not have an OSSF disposal system reduction.

(b) Effluent disposal system sizing. If the graywater reuse system or combined reuse system serving the single family residence is in compliance with Chapter 210, Subchapter F of this title, the effluent disposal system required in §285.33 of this title may be reduced in accordance with Table I in Figure: 30 TAC §285.81(b) of this section.

Attached Graphic

(c) Verification of plumbing entering the OSSF. A licensed master plumber shall evaluate and document, after the plumbing is installed, which sewage sources will be entering the OSSF. The documentation must be provided to the OSSF permitting authority.

(d) Increased wastewater strength. When graywater is removed from the total sewage stream, the remaining sewage stream entering the OSSF will have a higher organic strength. The resulting increase in sewage strength shall be determined in accordance with Table II in Figure: 30 TAC §285.81(d) of this section.

Attached Graphic

(e) If the effluent disposal system does not require secondary treatment, either a professional sanitarian or a professional engineer shall demonstrate with effective treatment design and supporting calculations that the proposed treatment system will reduce the effluent quality down to 140 milligrams per liter five-day biochemical oxygen demand (mg/l BOD5 ) prior to entering the effluent disposal system.

(f) If the effluent disposal system requires secondary treatment, then a professional engineer shall demonstrate with effective treatment design and supporting calculations that the effluent quality meets the levels outlined in §285.32(e) of this title (relating to Criteria for Sewage Treatment Systems).

(g) If the effluent disposal system is reduced based on the presence of a graywater reuse system or a combined reuse system, a reserve area equivalent to the reduced area shall be shown to be available for future construction of a disposal field should the graywater reuse system or combined reuse system be abandoned at a later date. The reserve area shall meet the setbacks required by §285.91(10) of this title (relating to Tables) and shall not be used for any surface improvements.

(h) Graywater or alternative onsite water, as defined in Chapter 210, Subchapter F of this title, shall not be applied to the surface of a reduced effluent disposal system.

(i) The reduced effluent disposal system is not sized to accommodate graywater. Therefore, there shall not be any physical connection between the graywater reuse system or the combined reuse system and any part of the OSSF without authorization from the OSSF permitting authority.

(j) In addition to the requirements outlined in Chapter 210, Subchapter F of this title, a graywater reuse system or a combined reuse system, used in association with a reduced effluent disposal system under this section, must have a storage tank capable of storing a volume of three days of graywater. The storage is necessary to prevent application of graywater during periods when the landscape is saturated.

(k) Before a license to operate is issued for a reduced effluent disposal system allowed under this section, an affidavit shall be properly filed and recorded in the deed records of the county. The affidavit must include the owner's full name, the legal description of the property, a statement that the permit for the OSSF is transferred to the new owner upon transfer of the property, a statement that the effluent disposal system is reduced due to the presence of a graywater reuse system or a combined reuse system, a statement that the specified reserve area shall not contain surface improvements, and a statement that the graywater reuse system or combined reuse system cannot be connected to the OSSF without obtaining a permit from the OSSF permitting authority.

(l) If the property owner of a graywater reuse system or a combined reuse system on a property served by a reduced effluent disposal system is convicted under or found in violation of any statute related to graywater or public health nuisance, and the system is not properly repaired in a timely manner, the OSSF permitting authority may require the graywater to be connected to the OSSF. If the OSSF permitting authority requires the graywater to be connected to the OSSF, the effluent disposal system must be expanded to accommodate all the flow required in §285.91(3) of this title, and the expansion must be permitted by the OSSF permitting authority.


Source Note: The provisions of this §285.81 adopted to be effective June 13, 2001, 26 TexReg 4115; amended to be effective January 6, 2005, 29 TexReg 12204; amended to be effective December 29, 2016, 41 TexReg 10378

Link to Texas Secretary of State Home Page | link to Texas Register home page | link to Texas Administrative Code home page | link to Open Meetings home page