TITLE 30ENVIRONMENTAL QUALITY
PART 1TEXAS COMMISSION ON ENVIRONMENTAL QUALITY
CHAPTER 115CONTROL OF AIR POLLUTION FROM VOLATILE ORGANIC COMPOUNDS
SUBCHAPTER CVOLATILE ORGANIC COMPOUND TRANSFER OPERATIONS
DIVISION 2FILLING OF GASOLINE STORAGE VESSELS (STAGE I) FOR MOTOR VEHICLE FUEL DISPENSING FACILITIES
RULE §115.221Emission Specifications

No person in the Beaumont-Port Arthur, Bexar County, Dallas-Fort Worth, El Paso, and Houston-Galveston-Brazoria areas, or in the covered attainment counties, as defined in §115.10 of this title (relating to Definitions), shall transfer, or allow the transfer of, gasoline from any tank-truck tank into a stationary storage container which is located at a gasoline dispensing facility, unless the displaced vapors from the gasoline storage container are controlled by one of the following:

  (1) a vapor control system which reduces the emissions of VOC to the atmosphere to not more than 0.8 pound per 1,000 gallons (93 mg/liter) of gasoline transferred; or

  (2) a vapor balance system which is operated and maintained in accordance with the provisions of §115.222 of this title (relating to Control Requirements).


Source Note: The provisions of this §115.221 adopted to be effective February 19, 1990, 15 TexReg 549; amended to be effective August 1, 1992, 17 TexReg 4683; amended to be effective May 22, 1997, 22 TexReg 4213; amended to be effective July 21, 1999, 24 TexReg 5488; amended to be effective October 2, 2014, 39 TexReg 7745; amended to be effective May 16, 2024, 49 TexReg 3292