(a) A wastewater treatment facility must use reclaimed
water in place of potable water in all treatment units, for wash down
water, and for irrigating the grounds within the boundaries of the
wastewater treatment facility.
(b) A wastewater treatment facility must include a
meter to measure reclaimed water use in the wastewater treatment facility.
(c) Reclaimed water may only be used after treatment
in a secondary treatment process. Untreated or partially treated wastewater
may not be used as reclaimed water. A reclaimed water system must
provide for screening or filtration, a backup pump with controls,
and a pressure-sustaining device such as a hydro-pneumatic tank.
(d) If disinfection is part of the treatment, reclaimed
water may only be used after it has been disinfected.
(e) Reclaimed water may be used within the wastewater
treatment facility with no further authorization from the executive
director if it is used in accordance with this section and §210.4(c)
of this title (relating to Notification).
|