(a) Purpose.
(1) The requirements in this section establish radiation
safety requirements and licensing and registration procedures for
using sources of radiation for industrial radiography and for certification
of industrial radiographers.
(2) The requirements in this section apply to licensees
and registrants who possess sources of radiation for industrial radiography,
including radiation machines, accelerators, and sealed radioactive
sources.
(3) Each licensee and registrant is responsible for
ensuring compliance with this chapter, license and registration conditions,
and orders of the department.
(4) Each licensee and registrant is responsible for
ensuring radiographic personnel performing activities under a license
or registration comply with this chapter, license and registration
conditions, and orders of the department.
(b) Scope.
(1) The requirements of this section are in addition
to and not in substitution for other applicable requirements of this
chapter.
(2) The requirements of the following sections of this
chapter apply to all licensed industrial radiographic operations:
(A) §289.201 of this chapter (relating to General
Provisions for Radioactive Material);
(B) §289.202 of this chapter (relating to Standards
for Protection Against Radiation from Radioactive Materials);
(C) §289.203 of this chapter (relating to Notices,
Instructions, and Reports to Workers; Inspections);
(D) §289.204 of this chapter (relating to Fees
for Certificates of Registration, Radioactive Material Licenses, Emergency
Planning and Implementation, and Other Regulatory Services);
(E) §289.205 of this chapter (relating to Hearing
and Enforcement Procedures);
(F) §289.251 of this subchapter (relating to Exemptions,
General Licenses, and General License Acknowledgements);
(G) §289.252 of this subchapter (relating to Licensing
of Radioactive Material); and
(H) §289.257 of this subchapter (relating to Packaging
and Transportation of Radioactive Material).
(3) The requirements of the following sections of this
chapter apply to all registered industrial radiographic operations:
(A) §289.203 of this chapter;
(B) §289.204 of this chapter;
(C) §289.205 of this chapter;
(D) §289.226 of this chapter (relating to Registration
of Radiation Machine Use and Services); and
(E) §289.231 of this chapter (relating to General
Provisions and Standards for Protection Against Machine-Produced Radiation).
(4) The requirements of §289.228 of this chapter
(relating to Radiation Safety Requirements for Industrial Radiation
Machines) apply to persons using analytical and other industrial radiation
machines subject to this section.
(5) The requirements of §289.229 of this chapter
(relating to Radiation Safety Requirements for Accelerators, Therapeutic
Radiation Machines, Simulators and Electronic Brachytherapy Devices)
apply to persons using accelerators subject to this section.
(c) Definitions. The following words and terms when
used in this section have the following meaning unless the context
clearly indicates otherwise.
(1) ANSI--American National Standards Institute.
(2) Annual refresher safety training--A review conducted
or provided by the licensee or registrant for its employees on radiation
safety aspects of industrial radiography. The review may include,
as appropriate, the results of internal audits, new procedures or
equipment, new or revised regulations, accidents or errors that have
been observed, and should also provide opportunities for employees
to ask safety questions.
(3) Associated equipment--Equipment, used in conjunction
with a radiographic exposure device used to make radiographic exposures,
that drives, guides, or comes in contact with the source, (such as,
guide tube, control tube, control cable (drive cable), removable source
stop, "J" tube, and collimator when it is used as an exposure head).
(4) Cabinet x-ray system--An x-ray system with the
x-ray tube installed in an enclosure independent of existing architectural
structures except the floor on which it may be placed. An x-ray tube
used within a shielded part of a building, or x-ray equipment that
may temporarily or occasionally incorporate portable shielding, is
not considered a cabinet x-ray system. The cabinet x-ray system is
intended to:
(A) contain at least that portion of a material being
irradiated;
(B) provide radiation attenuation; and
(C) exclude personnel from its interior during generation
of radiation.
(5) Certifiable cabinet x-ray system--An existing uncertified
x-ray system modified to meet the certification requirements specified
in 21 Code of Federal Regulations (CFR) §1020.40.
(6) Certification identification (ID) card--The document
issued by the department to individuals who have completed the requirements
stated in subsection (e)(2)(A) of this section.
(7) Certified cabinet x-ray system--An x-ray system
that has been certified as specified in 21 CFR §1010.2 as being
manufactured and assembled on or after April 10, 1975, as specified
in the provisions of 21 CFR §1020.40.
(8) Certifying entity--An entity that is:
(A) an independent certifying organization;
(B) an Agreement State whose industrial radiographer
certification program meets the applicable parts of 10 CFR Part 34,
Appendix A, Parts II and III for radioactive material; or
(C) a radiation control agency whose x-ray or combination
certification requirements are found to be equivalent to criteria
established by the Conference of Radiation Control Program Directors,
Inc..
(9) Collimator--A radiation shield placed on the end
of a guide tube or directly onto a radiographic exposure device to
restrict the size of the radiation beam when the sealed source is
cranked into position to make a radiographic exposure.
(10) Conference of Radiation Control Program Directors,
Inc. (CRCPD)--A 501(c)(3) nonprofit, non-governmental, professional
organization dedicated to radiation protection to serve as a common
forum for the many governmental radiation protection agencies to communicate
with each other and to promote uniform radiation protection regulations
and activities.
(11) Control cable (drive cable)--The cable connected
to the source assembly and used to drive the source from and return
it to the shielded position.
(12) Control mechanism (drive mechanism)--A device
enabling the source assembly to be moved from and returned to the
shielded position. A drive mechanism is also known as a crank assembly.
(13) Control tube--A protective sheath for guiding
the control cable. The control tube connects the control drive mechanism
to the radiographic exposure device.
(14) Crank-out device--The control cable, control tube,
and drive mechanism used to move the sealed source to and from the
shielded position to make an industrial radiographic exposure.
(15) Exposure head--A device that locates the gamma
radiography sealed source in the selected working position. An exposure
head is also known as a source stop.
(16) Field station--A facility where licensed material
or radiation machines are stored or used and from which equipment
is dispatched to temporary job sites.
(17) Guide tube--A flexible or rigid tube, such as
a "J" tube, for guiding the source assembly and the attached control
cable from the exposure device to the exposure head. The guide tube
may also include the connections necessary for attachment to the exposure
device and to the exposure head.
(18) Independent certifying organization--An independent
organization meeting the criteria of 10 CFR Part 34, Appendix A, for
radioactive material, or comparable standards for x-ray machines.
(19) Industrial radiography (radiography)--A non-destructive
testing method using ionizing radiation, such as gamma rays or x-rays,
to make radiographic images for the purpose of detecting flaws in
objects without destroying them.
(20) Lay-barge radiography--Industrial radiography
performed on any water vessel used for laying pipe.
(21) Lock-out survey--A radiation survey performed
to determine a sealed source is in its fully shielded position before
moving the radiographic exposure device or source changer to a different
temporary job site or before securing the radiographic exposure device
or source changer against unauthorized removal.
Cont'd... |