<<Prev Rule

Texas Administrative Code

Next Rule>>
TITLE 30ENVIRONMENTAL QUALITY
PART 1TEXAS COMMISSION ON ENVIRONMENTAL QUALITY
CHAPTER 106PERMITS BY RULE
SUBCHAPTER OOIL AND GAS
RULE §106.354Iron Sponge Gas Treating Unit

Iron sponge gas treating units processing streams containing less than 60 pounds per hour of hydrogen sulfide are permitted by rule provided that the following conditions of this section are satisfied:

  (1) the plant is located at least 1/4 mile from any recreational area or residence or other structure not occupied or used solely by the owner of the facility or the owner of the property upon which the facility is located;

  (2) during replacement of the iron oxide impregnated chips, the unit is:

    (A) isolated from the main system and the pressure is reduced to 0.5 psia or less through a gas-fired flare; or

    (B) sulfur compound emissions to the atmosphere do not exceed one ton per replacement;

  (3) the spent iron oxide chips being replaced are properly handled to avoid spontaneous ignition and avoid an odor nuisance.


Source Note: The provisions of this §106.354 adopted to be effective March 14, 1997, 22 TexReg 2439; amended to be effective September 4, 2000, 25 TexReg 8653

Link to Texas Secretary of State Home Page | link to Texas Register home page | link to Texas Administrative Code home page | link to Open Meetings home page