RULE §535.232Standards of Practice: Minimum Inspection Requirements for Appliances
ISSUE 11/14/2008
ACTION Final/Adopted
Preamble Texas Admin Code Rule

(a)Dishwasher. The inspector shall report as Deficient:

  (1)inoperative unit(s);

  (2)rust on the interior of the cabinet or components;

  (3)failure to drain properly;

  (4)the presence of active water leaks; and

  (5)deficiencies in the:

    (A)door gasket;

    (B)control and control panels;

    (C)dish racks;

    (D)rollers;

    (E)spray arms;

    (F)operation of the soap dispenser;

    (G)door springs;

    (H)dryer element;

    (I)door latch and door disconnect;

    (J)rinse cap;

    (K)secure mounting of the unit; and

    (L)backflow prevention.

(b)Food waste disposer. The inspector shall report as Deficient:

  (1)inoperative unit(s);

  (2)unusual sounds or vibration level;

  (3)the presence of active water leaks; and

  (4)deficiencies in the:

    (A)splash guard;

    (B)grinding components;

    (C)exterior casing; and

    (D)secure mounting of the unit.

(c)Range exhaust vent. The inspector shall report as Deficient:

  (1)inoperative unit(s);

  (2)a vent pipe that does not terminate outside the structure, if the unit is not of a re-circulating type or configuration;

  (3)inadequate vent pipe material;

  (4)unusual sounds or vibration levels from the blower fan(s);

  (5)blower(s) that do not operate at all speeds; and

  (6)deficiencies in the:

    (A)filter;

    (B)vent pipe;

    (C)light and lens;

    (D)secure mounting of the unit; and

    (E)switches.

(d)Electric or gas ranges, cooktops, and ovens. The inspector shall report as Deficient:

  (1)inoperative unit(s);

  (2)the lack of a gas shut-off valve;

  (3)gas leaks; and

  (4)deficiencies in the:

    (A)controls and control panels;

    (B)thermostat(s) sensor support;

    (C)glass panels;

    (D)door gasket(s), hinges, springs, closure, and handles;

    (E)door latch;

    (F)heating elements or burners;

    (G)thermostat accuracy (within 25 degrees at a setting of 350°F);

    (H)drip pans;

    (I)lights and lenses;

    (J)clearance to combustible material;

    (K)anti-tip device;

    (L)gas shut-off valve(s) and location(s);

    (M)gas connector materials and connections; and

    (N)secure mounting of the unit.

(e)Microwave oven. The inspector shall:

  (1)inspect built-in units; and

  (2)report as Deficient:

    (A)inoperative unit(s); and

    (B)deficiencies in the:

      (i)controls and control panels;

      (ii)handles;

      (iii)the turn table;

      (iv)interior surfaces;

      (v)door and door seal;

      (vi)glass panels;

      (vii)lights and lenses;

      (viii)secure mounting of the unit; and

      (ix)operation, as determined by heating a container of water or with other means of testing.

(f)Trash compactor. The inspector shall report as Deficient:

  (1)inoperative unit(s);

  (2)unusual sounds or vibration levels; and

  (3)deficiencies in the secure mounting of the unit.

(g)Mechanical exhaust vents and bathroom heaters. The inspector shall report as Deficient:

  (1)inoperative unit(s);

  (2)unusual sounds, speed, and vibration levels;

  (3)vent pipes that do not terminate outside the structure;

  (4)a gas heater that is not vented to the exterior of the structure; and

  (5)the lack of an exhaust ventilator in required areas.

(h)Garage door operators. The inspector shall report as Deficient:

  (1)inoperative unit(s);

  (2)door locks or side ropes that have not been removed or disabled; and

  (3)deficiencies in:

    (A)installation;

    (B)condition and operation of the garage door operator;

    (C)automatic reversal during the closing cycle;

    (D)electronic sensors;

    (E)the control button; and

    (F)the emergency release components.

(i)Doorbell and chimes. The inspector shall report as Deficient:

  (1)inoperable unit(s); and

  (2)deficiencies in components.

(j)Dryer vents. The inspector shall report as Deficient:

  (1)improper routing and length of vent pipe;

  (2)inadequate vent pipe material;

  (3)improper termination;

  (4)the lack of a dryer vent system when provisions are present for a dryer; and

  (5)damaged or missing exterior cover.

(k)Specific limitations for appliances. The inspector is not required to:

  (1)operate or determine the condition of other auxiliary components of inspected items;

  (2)test for microwave oven radiation leaks;

  (3)inspect self-cleaning functions;

  (4)test trash compactor ram pressure; or

  (5)determine the adequacy of venting systems.

This agency hereby certifies that the adoption has been reviewed by legal counsel and found to be a valid exercise of the agency's legal authority.

Filed with the Office of the Secretary of State on November 3, 2008

TRD-200805777

Devon V. Bijansky

Assistant General Counsel

Texas Real Estate Commission

Effective date: February 1, 2009

Proposal publication date: September 5, 2008

For further information, please call: (512) 465-3900



Next Page Previous Page

Link to Texas Secretary of State Home Page | link to Texas Register home page | link to Texas Administrative Code home page | link to Open Meetings home page