    (C) If the amount of hazardous waste accumulated on-site at or near the point of generation exceeds the maximum amount specified in subsection (f)(4)(A) of this section, the generator must, with respect to such excess waste, comply with all applicable provisions of this section within three days of the date that such maximum amount is exceeded.

  (5) Episodic Generation. Except as otherwise provided in this paragraph, if a generator's classification varies from one month to another, the hazardous oil and gas waste generated during any particular month shall be managed in accordance with the requirements applicable to the generator's classification for that month.

    (A) If hazardous oil and gas waste generated by a generator who is classified as a CESQG during a particular month is mixed with waste generated in a month during which the generator is considered an LQG, the mixture shall be managed in accordance with the standards applicable to LQGs.

    (B) If hazardous oil and gas waste generated by a generator who is classified as a CESQG during a particular month is mixed with waste generated in a month during which the generator is considered an SQG, the mixture shall be managed in accordance with the standards applicable to SQGs.

    (C) If hazardous oil and gas waste generated by a generator who is classified as an SQG during a particular month is mixed with waste generated in a month during which the generator is considered an LQG, the mixture shall be managed in accordance with the standards applicable to LQGs.

(g) Notification. A person who is considered an LQG or SQG under the provisions of this section must notify the commission of the activities of such person that are subject to the provisions of this section and obtain an EPA ID number by filing the prescribed form (currently EPA Form 8700-12) with the commission. Such notification must be made upon the later of 90 days after the effective date of this section or within ten days of the date that the LQG or SQG becomes subject to the provisions of this section.

(h) Preparedness and Prevention.

  (1) General. In addition to all other applicable requirements of this section, all generators of hazardous oil and gas waste shall employ reasonable and appropriate measures (considering the nature and location of the facility and the types and quantities of hazardous oil and gas waste maintained at the site) in the operation and maintenance of his or her generation site to minimize the possibility of a fire, explosion, or any unplanned sudden or non-sudden release of hazardous oil and gas wastes or hazardous oil and gas waste constituents to air, soil, or surface water that could threaten human health or the environment.

  (2) LQGs and SQGs. LQGs and SQGs who accumulate hazardous oil and gas waste at the generation site must comply with the provisions applicable to owners or operators of 40 CFR, Part 265, Subpart C (concerning preparedness and prevention).

(i) Contingency Plan and Emergency Procedures.

  (1) LQGs. LQGs who accumulate hazardous oil and gas waste at the generation site must comply with the provisions applicable to owners or operators of 40 CFR, Part 265, Subpart D (concerning contingency plan and emergency procedures).

  (2) SQGs. SQGs who accumulate hazardous oil and gas waste at the generation site must comply with the provisions of 40 CFR, §262.34(d)(5) (concerning emergency response).

(j) Personnel Training. LQGs who accumulate hazardous oil and gas waste at the generation site must comply with the provisions applicable to owners or operators of 40 CFR, §265.16 (concerning personnel training).

(k) Standards for Use of Containers.

  (1) LQGs. LQGs accumulating hazardous oil and gas waste in containers must:

    (A) comply with the provisions applicable to owners or operators of 40 CFR, Part 265, Subpart I (concerning use and management of containers);

    (B) clearly mark each container being used to accumulate hazardous oil and gas waste on-site, in a manner and location visible for inspection, with the date accumulation of such hazardous oil and gas waste begins; and

    (C) clearly label or mark each container being used to accumulate hazardous oil and gas waste on-site with the words "Hazardous Waste."

  (2) SQGs. SQGs accumulating hazardous oil and gas waste in containers must:

    (A) comply with the provisions applicable to owners or operators of 40 CFR, Part 265, Subpart I, except §265.176 (concerning distance from property lines);

    (B) clearly mark each container being used to accumulate hazardous oil and gas waste on-site, in a manner and location visible for inspection, with the date accumulation of such hazardous oil and gas waste begins; and

    (C) clearly label or mark each container being used to accumulate hazardous oil and gas waste on-site with the words "Hazardous Waste."

  (3) CESQGs. The provisions of this paragraph apply to CESQGs only.

    (A) Hazardous oil and gas waste generated by a CESQG may be mixed with non-hazardous waste even though the resultant mixture exceeds the quantity limitations of subsection (f)(1) of this section, unless the mixture exhibits any of the hazardous waste characteristics of the hazardous oil and gas waste in the mixture, as determined under subsection (e)(1)(D)(ii) of this section.

    (B) If a CESQG's wastes are mixed with used oil, the mixture is subject to the requirements 40 CFR, Part 279 if the mixture is destined to be burned for energy recovery. Any material produced from such a mixture by processing, blending, or other treatment is also so regulated if it is destined to be burned for energy recovery.

(l) Standards for Use of Tank Systems.

  (1) LQGs. LQGs accumulating hazardous oil and gas waste in tanks must:

    (A) comply with the provisions applicable to owners or operators of 40 CFR, Part 265, Subpart J, except §265.197(c) and §265.200;

    (B) comply with the provisions applicable to owners or operators of 40 CFR, §265.111 and §265.114 (concerning closure performance standards and disposal of contaminated equipment and media); and

    (C) clearly label or mark each tank being used to accumulate hazardous oil and gas waste with the words "Hazardous Waste."

  (2) SQGs. SQGs accumulating hazardous oil and gas waste in tanks must:

    (A) comply with the provisions of 40 CFR, §265.201 (concerning accumulation of waste in tanks by small quantity generators); and

    (B) clearly label or mark each tank being used to accumulate hazardous oil and gas waste with the words "Hazardous Waste."

(m) Disposition of Hazardous Oil and Gas Waste.

  (1) On-site Treatment, Storage, Disposal, Recycling, and Reclamation. Except as otherwise specifically provided in this section, no person may treat, store, dispose of, recycle, or reclaim any hazardous oil and gas waste on-site.

  (2) Transport to Authorized Facility.

    (A) Except as otherwise specifically provided in this section and subject to all other applicable requirements of state or federal law, a generator of hazardous oil and gas waste must send his or her waste to one of the following categories of facilities for treatment, storage, disposal, recycling, or reclamation:

      (i) an authorized recycling or reclamation facility;

      (ii) an authorized treatment, storage, or disposal facility;

      (iii) a facility located outside the United States, provided that the requirements of subsection (v)(1) of this section (relating to exports of hazardous waste) are met;

      (iv) a transfer facility, provided that the requirements of subsection (w)(3) of this section are met;

      (v) if the waste is generated by a CESQG, a facility permitted, licensed, or registered by a state to manage municipal or industrial solid waste; or

      (vi) if the waste is generated by a CESQG, a centralized waste collection facility (CWCF) that meets the requirements of subsection (m)(3) of this section.

    (B) Notwithstanding any contrary provision of this subsection, hazardous oil and gas wastes may be treated or stored on-site in an elementary neutralization unit or a totally enclosed treatment facility. If a hazardous oil and gas waste that is ignitable under 40 CFR, §261.21 (other than DOO1 High TOC Subcategory wastes defined in 40 CFR, §268.42, Table 2) or that is corrosive under 40 CFR, §261.22 is being treated in an elementary neutralization unit or a wastewater treatment unit to remove the characteristic before land disposal, the owner or operator must comply with the requirements of 40 CFR, §264.17(b).